Short description

Hydraulic model tests were conducted to investigate the hydraulic conditions for the following structures and reservoir areas:
Fierza HW spillway with
- Dugout with jump
- End area of the relief tunnel
- Energy conversion in the adjacent water section
The focus of the 1:51.25 scale model tests was on the hydraulics of the outlet structures, their positioning, and the reservoir sections near the outlets or the impact area of the impinging jets.